Call 07942702135 67% Response Rate

our range

Tyco Sprinkler

Pioneers in the industry, we offer tyco pendent upright sprinkler, tyco pendent sprinkler 68 deg standard response ul & fm, tyco pendent sprinkler 68 deg quick response ul & fm, tyco sidewall sprinkler 68 deg extended throw quick response k 80, tyco upright sprinkler 68 deg quick response ul & fm and tyco concealed sprinkler 68 deg standard response ul & fm with cover plate from India.
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
  • Tyco Pendent Upright Sprinkler
Tyco Pendent Upright Sprinkler

Tyco Pendent Upright Sprinkler

Rs 195  / PieceGet Best Price

Product Brochure

MaterialBrass
DesignUpright
BrandTyco
Temperature Rating68 Degree C
K-FACTOR (Discharge Rate)5.6 US (80 metric)
Bulb Size5 mm
Thread Size1/2 NPT
Wrench RecessedW7
ApprovalUL, C-UL, FM, LPCB, VdS, CE
Thread1/2"
Temperature135, 155, 175, 200, 286, 360, Open degree F
SIN NumbersTY315, TY325
WrenchW6
For catering the variegated needs of our clients, we are deeply engrossed in offering a qualitative array of Tyco Recessed Pendent Sprinkler.

View Complete details

get quote request a call back
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM
Tyco Pendent  Sprinkler 68 Deg Standard Response UL & FM

Tyco Pendent Sprinkler 68 Deg Standard Response UL & FM

Rs 190  / PieceGet Best Price

Product Brochure

MaterialBrass
BrandTyco
K-FACTOR (Discharge Rate)5.6 US (80 metric)
Bulb Size5 mm
Mounting TypeCeiling Mounted
ResponseStandard Response
ModelTFP152
WrenchW6
SeriesTY-FRB
HazardLight Hazard/Ordinary Hazard
Thread1/2"
SIN NumbersTY325
ApprovalUL,C-UL,FM,NYC,LPCB
Temperature57, 68, 79, 93, 141, 182
Series TY-B, 5.6 K-factorUpright, Pendent, and Recessed Pendent SprinklersStandard Response, Standard Coverage, The TYCO Series TY-B, 5.6 K-factor,Upright (TY315) and Pendent (TY325)Sprinklers described in this data sheetare standard response, standard coverage,decorative 5 mm glass bulbtype spray sprinklers designed for usein light, ordinary, or extra hazard, commercialoccupancies such as banks,hotels, shopping malls, factories, refineries,and chemical plants.

View Complete details

get quote request a call back
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM
Tyco Pendent  Sprinkler 68 Deg Quick Response UL & FM

Tyco Pendent Sprinkler 68 Deg Quick Response UL & FM

Rs 360  / PieceGet Best Price

Product Brochure

BrandTyco
ResponseQuick Response
HazardLight Hazard/Ordinary Hazard
Temperature135,155,175,200,286 degree F
SIN NumbersTY313,TY323
WrenchW6
ModelTFP172
Thread1/2 Inch
SeriesTY-FRB
ApprovalUL,C-UL,FM,LPCB,VdS,CE
Owing to our enriched industrial experiences, we are committed to providing a wide variety of excellent quality Tyco TFP 172 Recessed Pendent Sprinklers.

View Complete details

get quote request a call back
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
  • Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80
Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80

Tyco Sidewall Sprinkler 68 Deg Extended Throw Quick Response K 80

Rs 510  / PieceGet Best Price

Product Brochure

MaterialBrass
BrandTyco
Bulb Size3 MM
Temperature Rating57, 68, 79
Size1/2 inch
Working Pressure250 PSI
FinishingBrass
ColorRed
K FactorK 80
Series TY-FRB – 5.6 and 8.0 K-factorExtended Coverage Horizontal Sidewall SprinklersQuick and Standard Response (Light Hazard), TYCO Series TY-FRB 5.6 and 8.0K-factor Extended Coverage HorizontalSidewall Sprinklers Quick andStandard Response (Light Hazard) aredecorative 3 mm glass bulb type spraysprinklers designed for use in hydraulicallycalculated sprinkler systems inlight hazard, commercial occupanciessuch as churches, restaurant seatingareas, hotels, educational facilities,offices, etc. With their coverage upto 16 ft (4,9 m) wide by 24 ft (7,3 m)long, they are designed for installationalong a wall or the side of a beam andjust beneath a smooth ceiling. Horizontalsidewall (HSW) sprinklers arecommonly used instead of pendent orupright sprinklers due to aesthetics orbuilding construction considerations,where piping across the ceiling is notdesirable.The fast response thermal sensitivityrating of the Series TY-FRB, 3 mm bulbtype sprinklers provides for a quickresponse extended coverage (QREC)rating for many of the coverage areasdetailed in Tables B and C.

View Complete details

get quote request a call back
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
  • Tyco Upright Sprinkler 68 Deg Quick Response UL & FM
Tyco Upright Sprinkler 68 Deg Quick Response UL & FM

Tyco Upright Sprinkler 68 Deg Quick Response UL & FM

Rs 370  / PieceGet Best Price

Product Brochure

MaterialBrass
BrandTyco
Bulb Size3 mm
Temperature Rating57, 68, 79, 93, 141, 182
Mounting TypeWall Mounted
Size1/2 inch
Working Pressure250 PSI
ColorRed
K FactorK 80
Owing to our enriched industrial experiences, we are committed to providing a wide variety of excellent quality Tyco TFP 172 Recessed Pendent Sprinklers.

View Complete details

get quote request a call back
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
  • Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate
Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate

Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate

Rs 950  / PieceGet Best Price

Product Brochure

MaterialBrass
BrandTyco
Bulb Size5 mm
Temperature Rating68 Deg
Mounting TypeCeiling Mounted
Size1/2 inch
Working Pressure250 PSI
FinishingChrome
ColorBulb Color Red
Discharge AreaK= 5.6 GPM/psi1/2 (80,6 LPM/bar1/2)
K FactorK 80
Tyco Concealed Sprinkler 68 Deg Standard Response UL & FM with Cover Plate, The TYCO Series RFII 5.6 K-factor,“Royal Flush II” Concealed PendentSprinklers Quick Response (3-mmbulb) and Standard Response (5-mmbulb), are decorative sprinklers featuringa flat cover plate designed toconceal the sprinkler. These sprinklersare optimal for architecturally sensitiveareas such as hotel lobbies, officebuildings, churches, and restaurants.Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly.