Call 07942702135 76% Response Rate

Send Enquiry

our range

Addressable Fire Alarm System

Leading Wholesale Trader of ma-2000-02 2 loop addressable panel with inbuilt dual loops, ma-8000-02 4 loop addressable panel with inbuilt 4 loops, conventional - photoelectric smoke detector model 2351ec and morley ul fault isolator module hm/diso/ul from New Delhi.

MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops

  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
  • MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
MA-2000-02 2 Loop Addressable Panel with inbuilt dual loops
Get Best Quote
Rs 95,270  / PiecePrice on Request

Product Brochure

Usage/ApplicationCommercial
Number of Zone2
MaterialMild Steel (MS)
Model Name/NumberMA-2000
BrandMorley
Weight4.5 Kg
ColourWhite
MA-2000-02, 7 inch touch screen display ; 10000 Eventlog ; 2000 Zone logics; Loop Current 750 mA; inbuiltNetworking Port; 4 Access Levels ; 2000 Soft Zones .EN54 Part 2 & 4 Certified

View Complete details

Yes! I am Interested Request a call back

MA-8000-02 4 Loop Addressable Panel with Inbuilt 4 loops

MA-8000-02  4 Loop Addressable Panel with Inbuilt 4 loops
Get Best Quote
Rs 1,73,880  / PiecePrice on Request

Product Brochure

Usage/ApplicationCommercial
Number of Zone4
MaterialMild Steel (MS)
BrandMorley
expandable upto 6 /8 loops ; 7 inch touchscreen display ; 10000 Event log ; 2000 Zone logics;Loop Current 750 mA; inbuilt Networking Port; 4Access Levels ; 2000 Soft Zones . EN54 Part 2 & 4Certified

View Complete details

Yes! I am Interested Request a call back

CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC

  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
  • CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
CONVENTIONAL - Photoelectric Smoke Detector Model 2351EC
Get Best Quote
Rs 610  / PiecePrice on Request

Product Brochure

Automation GradeSemi-Automatic
Body MaterialABS Plastic
Operating Voltageto 30VDC
Brand/CompanyHoneywell
Weight105 G
CONVENTIONAL - Photoelectric Smoke DetectorModel 2351EC, Low profile design• Low current draw• Backward compatible with Series 100 detector range of bases• Wide operating voltage 8 to 30VDC• Bi-colour LED detector status indicator• Automatic drift compensation• Range of detector bases available• Tested and approved to EN54 – 7:2000 (Amendment 1)

View Complete details

Yes! I am Interested Request a call back

Morley UL Fault Isolator Module HM/DISO/UL

  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
  • Morley UL Fault Isolator Module HM/DISO/UL
Morley UL Fault Isolator Module HM/DISO/UL
Get Best Quote
Rs 2,290  / PiecePrice on Request

Product Brochure

TypeAddressable
System ComponentsFire Alarm Control Panel
BrandMorley UL IAS by Honeywell
Model Name/NumberMI/DISO
Automation GradeAutomatic
Relay OutputsAlarm Relay
AC Input Power15 to 30
Wall MountedYes
Country of OriginMade in India
HM/DISO/UL, The Morley-IAS loop isolator module is used on the Morley-IAS intelligent firealarm control panels to protect the system against wire-to-wire short circuits onthe analogue addressable loop wiring.The fault isolator modules should be placed between groups of sensors on theloop wiring to protect the loop if a short circuit fault occurs. If a short circuit faultoccurs, the two isolators located either side of the short circuit fault willautomatically sense the voltage drop, open their switches and remove thedevices from the rest of the loop. If the line voltage then rises above a fixedthreshold, indicating that the short circuit fault is removed, then the isolatormodule will automatically restore the power to the isolated group of devices.The MI-DISO isolator uses a unique mechanical design allowing each module tobe mounted either in a wall box or on a DIN rail. Irrespective of the mountingmethod chosen, the address switch is both visible and accessible for selection.To help engineers in the maintenance and fault finding process, both the LEDsand the address switches can be viewed without having to remove the cover ofthe mounting box. The LEDs, being multi colour, provide diagnostic informationregarding the status of the isolator.

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES